forked from 1b-agent/opencadstudio-upstream
Web: check the autosave deadline from the font-poll tick (#1775)
A ten-minute time::every on wasm piles up long setTimeouts in the shared wasmtimer driver until it stops waking every timer, which silenced the automation channel and drop-open about 8 s after load. Co-Authored-By: Claude Opus 5.5 <[email protected]>
This commit is contained in:
1 parent
814dd2e3d6
commit
d915489a67
2 files changed
+36
-5
No files matched your search
+4
-2
@@ -2512,8 +2512,10 @@ impl OpenCADStudio {
|
||||
let web_fonts = Subscription::none();
|
||||
// Periodic autosave (SAVETIME): a `.sv$` recovery copy beside the file
|
||||
// on native, an OPFS snapshot on web. SAVETIME is the interval in
|
||||
// minutes; 0 disables it.
|
||||
let autosave = if self.savetime_min > 0 {
|
||||
// minutes; 0 disables it. The web build checks the deadline from the
|
||||
// `PollWebFonts` tick instead: a long `time::every` there stalls every
|
||||
// other timer for its whole period (#1775).
|
||||
let autosave = if self.savetime_min > 0 && cfg!(not(target_arch = "wasm32")) {
|
||||
iced::time::every(std::time::Duration::from_secs(
|
||||
self.savetime_min as u64 * 60,
|
||||
))
|
||||
|
||||
Reference in new issue