Files
OneCAD-Draft/src
HakanandClaude Opus 4.7 2f751c08f4 fix(scene): drop Z gate in fit_all so high-elevation entities show
Civil 3D files can legitimately carry profile geometry at huge Z
(10^6+ units) inside an otherwise small XY footprint — long-section
polylines on a road, for example. fit_all's outlier gate previously
filtered any point whose |x|, |y|, or |z| exceeded 10× the header
extent half-size, which dropped those polylines and made ZOOM
EXTENTS center on the main drawing only, leaving the profile
geometry permanently invisible.

The gate exists to reject origin-stuck entities and Ray/XLine far
points, both of which manifest as large XY excursions after
world_offset subtraction. Z-axis outliers are not a known garbage
pattern, so the gate now only checks XY.

Co-Authored-By: Claude Opus 4.7 <[email protected]>
2026-05-13 10:05:38 +03:00
..
2026-05-12 10:36:15 +03:00
2026-05-12 10:36:15 +03:00
2026-05-12 10:36:15 +03:00
2026-03-22 14:56:27 +03:00