Files
OneCAD-Draft/src/app
Hakan SevenandClaude Opus 4.8 4164ef7111 fix(dimension): re-bake the *D block after in-place edits (#181)
OCS renders a dimension live from its definition points but exports a
baked *D block that other applications draw. An in-place edit (DIMTEDIT,
text override, DIMSPACE, any ReplaceEntity/ReplaceMany edit) changed the
dimension while leaving the old block, so the export kept the pre-edit
graphics — BricsCAD/ODA showed the stale dimension while OCS showed the
edit.

Add explode::invalidate_dim_block, which drops a dimension's baked *D
block (record + owned sub-entities, so no orphan blocks accumulate) and
clears block_name; bake_dimension_blocks then rebuilds a fresh block on
the next save. Call it from the in-place edit paths. The transform path
(MOVE/COPY/PASTE) keeps its own block in sync and is left untouched, so
dimensions loaded from other applications and not edited are preserved.

Co-Authored-By: Claude Opus 4.8 <[email protected]>
2026-07-08 10:23:48 +03:00
..
2026-06-18 21:18:09 +03:00