forked from 1b-agent/fieldcraft-upstream
Two oracle cases: the contact patch test on non-matching meshes in small and finite sliding, and Hertz's cylinder on a flat under force control (peak pressure, pressure distribution, subsurface stress). docs/fem.md describes the formulation, the literature survey its papers; ROADMAP M7 and parity are updated. Co-Authored-By: Claude Opus 5.5 <[email protected]> Claude-Session: https://claude.ai/code/session_01UhhZMBTviDQxZvwnyP89fo
30 lines
724 B
JSON
30 lines
724 B
JSON
{
|
|
"note": "FieldCraft's accepted results for this case, written by `cargo xtask oracle --bless`. A result outside its band fails CI.",
|
|
"values": {
|
|
"normal_force": {
|
|
"band": 1.133036636011328e-6,
|
|
"value": 1133.0366360113278
|
|
},
|
|
"peak_pressure": {
|
|
"band": 2.891953889449524e-6,
|
|
"value": 2891.953889449524
|
|
},
|
|
"pressure_x0296": {
|
|
"band": 2.325066800691437e-6,
|
|
"value": 2257.8357909118563
|
|
},
|
|
"pressure_x0367": {
|
|
"band": 2.0784005834495077e-6,
|
|
"value": 2078.4005834495074
|
|
},
|
|
"pressure_x0633": {
|
|
"band": 1.0,
|
|
"value": -0.0
|
|
},
|
|
"syy_depth": {
|
|
"band": 2.0991580228637247e-6,
|
|
"value": -2059.819639241533
|
|
}
|
|
}
|
|
}
|