forked from 1b-agent/fieldcraft-upstream
The window built a deformed copy of the model for every results plot, which drops the geometry surfaces, so after a fluid solve the bracket vanished and nothing else was drawn. A fluid step's plot keeps the part as it is and draws the engine's flow display through it (the same scene as the headless pictures): the field on a slice, the part coloured by the flow beside it and streamlines. The legend shows the field with its bands and the cells of its extremes (Max/Min mark and turn the view to them); the results panel swaps the deformation rows for the slice's normal and position, the obstacles' colours, the streamlines and a frame slider, all running the results.* commands. The status line describes the new commands. Part of #193.