"title": "NAFEMS LE1 elliptic membrane with 2D plane stress elements (quad8)",
"kind": "benchmark",
"source": "NAFEMS, The Standard NAFEMS Benchmarks, TNSB Rev. 3, October 1990, test LE1 (target σ_yy = 92.7 MPa at D); as reproduced in the Abaqus 2017 Benchmarks Guide, 'LE1: Plane stress elements—elliptic membrane'",
"quantities": [
{
"id": "syy_D",
"quantity": "σ_yy at D (2, 0)",
"measure": {
"command": "solve.probe",
"params": {
"step": "Load",
"at": [
[
2,
0,
0
]
]
},
"pointer": "/nodes/0/stress/1"
},
"value": 92.7,
"tolerance": {
"relative": 0.01
},
"reason": "the target is published to three figures; the stress extrapolated to the edge on a converged mesh adds a few tenths of a percent"
}
]
}