Files
OneCAD/crates/engine/src/cmd
63095fedb3 Sheet metal: a fold's fixed point on the sheet's face counts as on it (#685) (#958)
On a large thin sheet the probes around the fixed point stepped clean through
the sheet (twice the mesh tolerance of a 465 mm part is more than its 0.8 mm
thickness), so a point exactly on the face touched no material and the fold
was refused. The probes now also step a quarter of the thickness.

Co-authored-by: jonaswre <[email protected]>
Co-authored-by: Claude Opus 5.5 <[email protected]>
2026-10-14 00:14:49 -04:00
..