Add a dockable Block Editor palette with selectable Parameters, Actions,
Parameter Sets and Constraints pages, reusing shared dock controls, icons
and ribbon-style hover bubbles.
Parameters, Actions, Parameter Sets and Block Properties Table are UI
catalogs only. Their entries remain disabled; this commit does not add
parameter placement, dynamic action behavior, parameter-set authoring or
block properties table functionality.
The Constraints page connects its geometric and dimensional entries to
existing ribbon commands. It reuses their implementations and adds no new
constraint behavior.
Keep the palette specific to BEDIT and retain its placement and selected
page across closing/reopening and Test Block. Opening, closing, switching
pages and clicking disabled entries preserve the document, undo history
and any running command.
Validation: 7 palette tests, 57 dock checks and 46 ribbon checks passed
(overlapping groups); rendered pages inspected and native debug build passed.
Annotative text in DWG/DXF holds the model height of its default
(native) scale representation; other scales draw it at the ratio of the
two. OCS read the stored value as paper height and multiplied it by the
annotation scale again, so text from AutoCAD came out far too small
(#1734), and annotative text OCS wrote came out too small in AutoCAD.
- Rendering uses the active/native context ratio (1 when the object has
no representation for the displayed scale).
- TEXT with an annotative style asks for the paper height, stores the
model height of the creation scale and gets that context; MTEXT
starts from the model height; ANNOUPDATE converts a fixed style
height the same way.
- Properties: the Height row of annotative TEXT and MTEXT is the paper
height at the displayed scale, with the model height beside it, and
an edit converts back. MTEXT shows Annotative when it has contexts.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
IMAGEADJUST (alias IAD) takes the selected raster images or asks
"Select image(s):", then opens a dialog with a before/after preview of
the first image and brightness, contrast and fade rows (bar plus
stepper, whole numbers 0-100). Apply writes the values to every chosen
image as one undo step; restore defaults sets 50/50/0. Adds the
image_adjust automation action and the image-adjust locale group.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
FBXEXPORT (also EXPORTFBX) saves every 3D mesh of the drawing (solids,
surfaces and meshes, at full display resolution) as a binary FBX 7.4
file for visualisation tools: one model per object with its geometry,
face normals and a material in its display colour. Axes stay Z-up and
the unit scale follows the drawing's insertion units.
Refs #1502
Co-Authored-By: Claude Opus 5.5 <[email protected]>
MENUBAR 1 shows File, Edit, View, Insert, Format, Tools, Draw,
Dimension, Modify, Parametric and Help menus above the ribbon; every
entry runs an existing command, and a test keeps each entry pointing at
a registered command. RIBBONCLOSE hides the ribbon and RIBBON brings it
back, so the menus can replace it. Both choices persist.
Also translates the "File" label, which every locale had left in
English.
Refs #1450
Co-Authored-By: Claude Opus 5.5 <[email protected]>
ADJUST gathers raster images or PDF/DWF/DGN underlays (other objects are
dropped silently, pickfirst is used, a mixed set is refused), then asks the
image option (Brightness default) or the underlay option (last used), with
value prompts that offer the image's own value or the session's last
underlay fade/contrast, and Monochrome Yes/No. Invalid values re-prompt.
One undo step. -IMAGEADJUST, PDFADJUST, DWFADJUST and DGNADJUST take one
kind each. Raster image Brightness/Contrast/Fade move to an Image Adjust
section as whole numbers with 0-100 validation.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
PUBLISH now runs what PRINTALL does: pick the layouts, each plotted with
its own page setup, into one multi-page PDF or to the printer.
Refs #1124
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Ported from d719fb77 (#1717); the hatch draw-order, PDF and
recovery-settle hunks stay out (main owns those paths).
- La16 was still billed at 4 B/px: the no-conversion special case
keyed on native_bpp == 4, which La16 also is — but only Rgba8 is a
real move in into_rgba8, so La16's decode peak is 8. The case now
keys on the color type, and a table test pins every layout's peak
(plus GIF's screen+frame 8) so the accounting can't silently drift.
- json_values_match: an integer beyond f64 precision no longer matches
a float it merely rounds onto; a mixed pair matches only when the
float is whole and converts back to exactly that integer (also the
fuzz finding of 9262d63f).
- ocs-control.js resolves `ready` with the API object instead of
window.ocsControl, which is still undefined when the bridge already
exists as the script runs (built before the first settle, avoiding
the temporal-dead-zone throw of a later const); DATALINK on web says
the typed path is superseded by the picker instead of silently
discarding it.
(cherry picked from commit d719fb77)
Ported from 2c38de53 (#1717). Main already carries the hatch PDF draw
order fix (#1345), the numeric set_properties compare (#1348) and the
web open from bytes, so those parts stay out; what remains:
#1349 — window.ocsControl.ready/request promise wrapper with an
ocs-ready event (web/ocs-control.js, loaded by the web page), and the
startup donation prompt is suppressed once a control request is seen
(opt-in pre-boot via localStorage["opencadstudio.automation"] = "1").
docs/automation/web.md documents both. The control protocol stays at 1.
DATALINK CSV-to-table works on web (picker + bytes through the session
registry — was std::fs, silently dead); COLORSCHEME accepts System
(prefers-color-scheme on web, AppsUseLightTheme on Windows).
Decode accounting, made honest per the fix-of-fix review: into_rgba8
allocates the RGBA destination while the native buffer is alive for
every non-Rgba8 layout (L8 5, La8 6, Rgb8 7, L16 6, La16 8 B/px
peaks — the formula now says so), GIF bills the screen+frame
coexistence at 8 B/px, and TIFF drops the 3x multipliers both ways —
tiff 0.11 splits the given budget between frame and scratch (a total
ceiling), so the old double-billing refused honest 16-bit GeoTIFFs
~2.25x early while admitting hostile chunk transients at 3x.
(cherry picked from commit 2c38de53)
EXPORTSVG left the plot dialog's SVG device on, so a later EXPORTPDF still
offered a .svg file. The SVG save dialog and plot button texts had no
catalog entries.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Resolve conflicts from main's rustfmt pass by taking main's versions of
command.rs, style.rs, view/mod.rs, scene/mod.rs, ui/window/mod.rs and
ui/properties.rs and re-applying this branch's Graphic Attributes changes.
Add the Graphic Attributes strings to the new lo-LA catalog.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Claude-Session: https://claude.ai/code/session_01E1QnME6WJbD5iGFae1eeCb
Conflicts were additions on both sides, kept together: the Count palette
and Sheet Set toggles next to the Graphic Attributes toggle in the ribbon,
main's new locale groups and catalog entries next to graphic-attributes,
and module declarations. The palette code follows main's crate renames
(acadrust -> codec, cadkernel -> kernel).
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Claude-Session: https://claude.ai/code/session_01VgkJN8DEojuPTumAXLHotu
- Scale and Twist take an Expression evaluated with the drawing's
parameters; invalid input prints the reference message and asks again.
- The scale and twist prompts use the reference wording and defaults.
- The SWEEP prompts and refusal messages are in the locale catalog with
translations in every locale.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
MTEXT draws its stored text instead of re-evaluating fields on every
redraw. Fields update on their evaluation events as the reference does:
open (1), save (2, not autosave), plot (4) and REGEN/REGENALL (16), each
masked with the drawing's FIELDEVAL (variable dictionary, 0-31, with the
reference's prompt and message), and the new UPDATEFIELD command
(selection, attributes of selected block references, "N field(s)
found." / "N field(s) updated."). A Date field (on demand only) keeps
its value until UPDATEFIELD. The FIELDDISPLAY gray box now covers each
field's own glyphs, one box per line it spans, instead of the whole
text. Codec moved to the update_fields / field_spans revision.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
- refresh_table_block no longer runs for every table change: only tables
whose picture reference this app dropped while editing them (and new
tables without one), never on appearance-only bumps. Moved, restyled or
freshly opened tables keep their authored *T block. TABLE edits now drop
the picture reference like the other table edit paths.
- set_count_display recolours just the handles whose count class changed
(restyle path + recolor_meshes_for_handles); only entering or leaving
count mode rebuilds the whole drawing.
- Count colouring keeps insert instancing: counted and duplicate wires get
their own instance groups instead of dropping render_instance.
- The hatch backdrop takes the count colour too.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Point clouds: drawn from their scans, attached, cropped and stylized.
The fork's codec patch is resolved to the upstream pins: the point cloud
records landed in opencadcodec 5ef9376, carried through opencadkernel
68eeda1 and opencadgraph e204966.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Bug:
$ISOLINES (header i16) and Surface.u/v_isolines (file-controlled i16)
were only ever floored at 0, never capped, and were handed to the
tessellation kernel as the per-face isolate count - which draws
0..count isolines per face with no ceiling of its own. SETVAR ISOLINES
32767 (or a DWG carrying that header, or a Surface with u_isolines =
32767) turned every rebuild and every per-cursor preview of
PRESSPULL/REVOLVE/SWEEP/LOFT into a multi-million-vertex computation:
measured 4,259,966 edge vertices for one 12-unit cylinder preview.
Reproduce:
1. SETVAR ISOLINES 32767 (or open a DWG whose $ISOLINES is large, or
edit a Surface whose u_isolines is 32767).
2. Draw a circle and start REVOLVE (or PRESSPULL/SWEEP/LOFT), or shade
any 3D solid.
3. Before: the app allocates without bound - abort on memory failure or
a permanent freeze; previews recompute on every mouse move.
4. After: previews stay interactive; a hostile header renders exactly
like the largest value the Options slider can request.
Fix:
Cap each value at the ceiling this product already agrees on, where the
type changes from i16 to the kernel count: header $ISOLINES <= 64 (the
Options slider's own "Isolines per surface" range), Surface
u/v_isolines <= 200 (the plugin editor's writable range). One helper
(clamp_header_isolines) replaces all 11 copies of .max(0) as usize
across the entity/scene/control/display feed sites,
surface_isoline_counts clamps both axes, and SETVAR ISOLINES stores
x.clamp(0, 64) so the echo, slider and re-saved files agree with what
renders; file-sourced headers keep their raw stored value and are
clamped at consumption. Clamping is density-only: geometry, bounds and
saves are untouched. Three regression tests cover hostile surface
counts, the SETVAR entry, and a file-sourced header measured through
display tessellation (hostile renders like the slider ceiling, negative
renders like zero).
Scans (.rcs) and projects (.rcp) are read and their points drawn as
screen-sized dots, coloured by the cloud's stylization. The cloud's
placement carries its scale and rotation; its extents and crops stay in
the scan's coordinates. A missing scan shows the extents with the saved
path. -POINTCLOUDATTACH / POINTCLOUDATTACH, POINTCLOUDCROP and the
POINTCLOUD* settings follow the reference's prompts and messages, the
Properties list is the reference's, and a locked cloud is left alone by
edits.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
An image's transparency flag decides whether transparent pixels show what
is behind the image or draw in their stored colour: the image pass and PDF
plots now follow it (it was ignored, so every PNG alpha showed through).
TRANSPARENCY selects images and asks for the mode, defaulting to the first
image's current one.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
The codec and kernel repositories and crates are renamed opencadcodec and
opencadkernel. Inside OCS they are depended on under short keys, so code
reads `codec::`, `kernel::` and the new `graph::` (opencadgraph, the node
graph engine). File-format and protocol spellings stay as they were: the
ACIS product id `acadrust`, the ACADRUST_* switches and the plugin
version keys `acadrust_version` / `acadrust_source`.
A button left of MCP on the command line opens a translucent node graph
over the viewport, with a palette of object, input, math, logic, list,
text and geometry nodes added by click or drag. An object node owns
drawing entities and its rows are the Properties panel's own rows for
them: the single-object page is extracted from refresh_properties as
entity_property_sections, values use the control protocol's
property_json, and writes go through set_property_value with a property
target override, so the panel, MCP and the graph share one read/write
path. A list reaching an object row makes one entity per element. Each
graph action is one undo step; the canvas pans and zooms.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
The plot dialog asks CUPS printers for their sheets and margins; on Windows
the query was a stub, so every printer showed the paper catalogue with
unverified margins. The driver is now asked the way the plot dialog expects:
- windows_media (compiled and tested everywhere): the three parallel
DeviceCapabilities tables (ids, sizes in tenths of a millimetre, 64-WCHAR
names) become one PrinterMedia per distinct size — a rotated or
borderless twin folds onto its sheet, catalogue sheets keep their name,
unknown sizes carry the driver's — with the device's margins on every
entry and the driver's default sheet found by id or by user size.
- print_to_printer (Windows): DeviceCapabilitiesW for the tables, the
default DEVMODE for the default sheet, one portrait printer DC for the
unprintable margins (physical offsets and extents, per device — a
documented approximation). The DEVMODE fetch is shared with the print
path (with_printer_devmode).
- A direct print now asks the driver for the plot's own sheet (by id, or
as a user-defined size), so an A3 plot prints on A3 rather than shrunk
into the driver's default; a driver that refuses the sheet is asked for
the orientation alone.
- The capability cache remembers printers that could not be asked, so a
slow failing query runs once per session, not on every dialog open.
- PRINTERS <name> reports a printer's sheets, margins and default sheet.
Tests: names (NUL trim, full slot, lossy), media folding and dropping,
default by id / user size / none, DC margins, paper id lookup.
Co-Authored-By: Claude Opus 5 <[email protected]>
On Windows a plot with no printer chosen went to the PDF application's
bare "print" verb — whatever that application considered its default —
and a viewer without a "printto" verb (Edge, store readers) silently
dropped the printer the dialog had chosen. The dialog also never named the
system default, and a failed printer enumeration left only "Default" and
"PDF" with the reason written to a console nobody sees.
- The default printer is looked up by name (GetDefaultPrinterW) both for
the dialog's "System default printer (…)" entry and before every job.
- A pure route decision (plan_print_route) resolves "Default" to that
name and uses the PDF application only when it registered a "printto"
verb for .pdf (AssocQueryStringW); otherwise the job goes straight to
the spooler through the existing GDI path. The report says which:
"Sent to printer: NAME (direct print | via the PDF application)".
- list_printers reports the system's own error; the plot dialog shows it
under the printer row and the command line warns once. A desktop without
CUPS is an empty list, not an error.
- PRINTERS command: default printer, listed printers (or the error) and,
on Windows, the print route — a report to paste into an issue.
- Properties… on the Default entry opens that printer's preferences sheet.
- GDI path: the driver's dmSize is kept (its private data lives behind
it), the print raster is no longer memoised for the session, and a
spooled temporary PDF is removed.
Tests: route planning (named / blank / no default / printto or not), the
PRINTERS command; the two Windows-only GDI tests pass the resolved name.
Co-Authored-By: Claude Opus 5 <[email protected]>